Description
							OL-COST and OL-COST+ are analog single zone standalone Leak Detection Terminals, designed for interfacing with sensing cables (Water and Acid) manufactured by OmniLeak. The primary use of these devices is to monitor one zone with a maximum of 120m leak detection sensing cables for conductive liquids. The adjustable alarm threshold helps us to adjust the sensitivity of the sensing cable connected (Water or Acid).						
				Primary Response from the OL-COST/OL-COST+:
- In the Event of a Leak in the sensing cable connected; an audible alarm is triggered, the leak LED (red) and the volt-free relay associated is activated. The leak location to the nearest meter is displayed (OL-COST+ only)
 - In the Event of a Cable Break in the sensing cable or leader cable connected; an audible alarm is triggered with the Cable Break LED (amber) and the volt-free relay associated is activated
 
Secondary Response from the OL-COST/OL-COST+:
- High-level interfacing to BMS/DCS/SCADA is implemented through Modbus RTU or Modbus TCP
 
															
							Photos and illustrations are not contractually binding and are subject to change without notice.						
				Information of the Panel :-
- Leak location to the nearest meter (OL-COST+ only).
 - LED’ for Different status of the Panel
- Power Supply Normal (Green)
 - Leak Alarm (Red)
 - Cable Break (Amber)
 
 - Alarm Silence button on the front to mute the alarm.
 - Volt-free relay gets activated to the specific alarm and it will remain activated as long as the alarm is physically active.
 - When the fault is physically cleared the LED’s and relays go back to its normal status.
 
Features and Benefits
- Standalone system to monitor maximum of 120m of sensing cable
 - Adjustable alarm threshold (low to high)
 - Audible sounder with silence button.
 - Leak location in meters, Power, Leak and Cable Break LED’s
 - Volt-free Relay contacts for:-
- Power Failure
 - Leak Alarm
 - Cable Break/Trouble
 
 - Remote monitoring (Modbus RS485 or TCP/IP)
 
Typical Applications
- Leak detection in FCU units with standalone panel.
 - Remote areas where unmanned sites are located.
 - Installed where only the leak location is required.
 - Small rooms where only a few meters are to be protected.
 
Compatible Acquisition Modules and Remote Devices
							OL-CLS						
				
							Analog Sensor cable for conductive liquids – lengths of 3m, 7m, 15m
(30m – limited availability, MOQ applies)
						
				
							OL-ALS						
				
							Analog Sensor cable for Acid – length of 3m, 7m, 15m
(30m – limited availability, MOQ applies)
						
				Technical Data
							Alarm Threshold						
				
							Yes, through potentiometer on PCB						
				
							Dimensions (LxWxD)						
				
							135x75x50mm						
				
							Weight						
				
							230g with the plastic glands						
				
							Fire Rating						
				
							UL94-HB						
				
							Ingress Rating 
						
				
							IP54/NEMA 3S – indoor use only 						
				
							Operating Temperature Range						
				
							0°C to +55°C						
				
							Power Supply Input						
				
							100-240VAC or 12-24VDC (Optional)						
				
							Power Consumption						
				
							1VA or 0.75W Maximum						
				
							Audible Sounder
						
				
							80dB max. Buzzer with Silence button						
				
							Relay Contact						
				
							Power Failure + Leak + Cable Break :- SPDT (NO/NC)						
				
							Trouble Relay Switching Capacity
						
				
							Switching current – 0.5 A at 250 VAC, 1A at 30 VDC						
				
							Alarm Relay Switching Capacity	
						
				
							Switching current – 5 A at 250 VAC, 10A at 30 VDC						
				
							Supported Protocol (Monitoring)						
				
							Modbus RS485 or Modbus TCP/IP						
				
							Maximum Length of Cable						
				
							OL/COST: 50m; OL-COST+: 120m; Lead Cable: 100m 
						
				
							Installation						
				
							Wall-mounted						
				
							OL-COST/OL-COST+ “Cost Optimised Sensor Terminals” are low powered devices that shall be installed according to the relevant local regulations and installed by qualified personnel						
				Product Codes
							OL-COST+						
				
							“Cost Optimised Sensor Terminal Plus” Water alarm unit with display and location, audible alarm, alarm threshold adjustment, 2 relays, 100-240VAC or 12-24VDC power supply. Maximum sensor cable length: 120 m						
				
							OL-COST						
				
							“Cost Optimised Sensor Terminal” Water alarm unit with audible alarm, with alarm threshold adjustment, 2 relays, 100-240VAC or 12-24VDC power supply. Maximum sensor cable length: 50 m						
				Manufacturer
							OmniLeak – France
32-34 Rue des Osiers 78 310 COIGNIERS
Paris, France.
Email:- admin@omnileak-me.com
Web:- www.omnileak-me.com
				32-34 Rue des Osiers 78 310 COIGNIERS
Paris, France.
Email:- admin@omnileak-me.com
Web:- www.omnileak-me.com
															
            
      