Our Liquid Leak Detection Alarm Units

Intended for all types of building, particularly; for office buildings, data centers, banks, museums, airport, stadiums, high-rise buildings, or department stores, our detection units allow automatic and instantaneous detection of water, acid or hydrocarbon liquid leaks.

Why install a leak detection unit?
To avoid recurring leaks and reduce the amount of network repair costs.
To minimize damage to your equipment, your data or your floor covering (parquet, tiles, etc.).
Designed in France by our team, our liquid leak detection units are made to measure after taking into account your specific needs.
We have put forward two technical solutions at your disposal:
  • Digital Addressable Alarm Unit with localization, which allows you to locate the leak within a radius of one meter. Pin point location of leak in floor map graphics. Redundancy loop back.
  • Analog Leak Detection Alarm Unit with or  without localization, with audible and visual alarm.
Description

Our OL-ECAT is a high-performance addressable alarm terminal with 7- or 12-inch touchscreen controller. The controller can monitor 4 digital outputs with 40 sensing cables up to 160 sensing
cables overall (2400m). It has a touch screen with built-in maps and the display the pin-point location of the leak on maps. The OL-ECAT control unit locates leaks precisely to the nearest meter. The OL-ECAT unit allows you to detect several leaks simultaneously. Its history can manage up to 5000 events. The OL-ECAT solution is able to handle the sensitivity of sensing cable leakage. The redundancy
optional loop back allows the system functional in the event of any cable breaks. Modbus / TCP IP communication modes as well as connection to a mobile network are available. Email notifications to the
client’s network.

Features and Benefits

  • Very long range of leak detection circuit & a pin-point
    location of fault in the circuit
  • Easy T-branching – no special devices/components needed
  • Adjustable alarm threshold (sensitivity 1-9)
  • Can be installed in humid environments
  • Able to interface with sensor cables and modules for various
    types of liquids as water, acids, bases, hydrocarbons, organic
    solvents, etc.
  • Leak detection in data centers and mission
    critical infrastructure.
  • Banking and commercial Buildings
  • Pump Rooms
  • HVAC Plant rooms
  • Remote chemical facilities
  • Remote chemical facilities
  • Chilled water piping applications
  • Telecom and High-Rise Buildings
  • Stadiums and Museums
  • Tank farms & Airports
Description
Our OL-ASAT is a high-performance addressable alarm terminal with 7 touchscreen controller. The controller can monitor 1 or 2 digital outputs with 10 sensing cables up to 20 sensing cables overall (300m per circuit). It has a touch screen with built-in maps and the display the pin-point location of the leak on maps. The OL-ASAT control unit locates leaks precisely to the nearest meter. The OLASAT unit allows you to detect several leaks simultaneously. Its history can manage up to 3000 events. The OL-ASAT solution is able to handle the sensitivity of sensing cable leakage. The redundancy optional loop back allows the system functional in the event of any cable breaks. Modbus / TCP IP communication modes as well as connection to a mobile network are available. Email notifications to the client’s network.

Features and Benefits

  • long range of leak detection circuit & a pinpoint location of fault in the circuit
  • Easy T-branching – no special devices/components needed
  • Adjustable alarm threshold (sensitivity 1-9)
  • Can be installed in humid environments
  • Able to interface with sensor modules for various types of liquids as water, acids, bases, hydrocarbons, organic solvents, etc.
  • Leak detection in data centers and commercial buildings
  • Monitoring of storage tanks and fuel lines of emergency generators
  • Monitoring of Military and Scientific facilities
  • Leak detection in chemical and petrochemical plants
Description
OL-COST+ is an analog single zone standalone Leak Detection Terminal, designed for interfacing with sensing cables (Water and Acid) manufactured by OmniLeak. The primary use of these device is to monitor one zone with a maximum of 120m leak detection sensing cables for conductive liquids. The adjustable alarm threshold helps us to adjust the sensitivity of the sensing cable connected (Water or Acid). Alarm silence button will enable to sound off. Primary Response from the OL-COST/OL-COST+:
  • In the Event of a Leak in the sensing cable connected; an audible alarm is triggered, the leak LED (red) and the volt-free relay associated is activated. The leak location to the nearest meter is displayed OL-COST+ LCD Screen.
  • In the Event of a Cable Break in the sensing cable or leader cable connected; an audible alarm is triggered with the Cable Break LED (amber) and the volt-free relay associated is activated Secondary Response from the OL-COST+:
  • High-level interfacing to BMS/DCS/SCADA is implemented through Modbus RTU or Modbus TCP

Features and Benefits

  • Standalone system to monitor maximum of 120m of sensing cable
  • Adjustable alarm threshold (low to high)
  • Audible sounder with silence button.
  • Leak location in meters, Power, Leak and Cable Break LED’s
  • Volt-free Relay contacts for:
    • Power Failure
    • Leak Alarm
    • Cable Break/Trouble
  • Remote monitoring (Modbus RS485 or TCP/IP)

Typical Applications

  • Leak detection in FCU units with standalone panel.
  • Remote areas where unmanned sites are located.
  • Installed where only the leak location is required.
  • Small rooms where only a few meters are to be protected.
Description
OL-COST is an analog single zone standalone Leak Detection Terminals designed for interfacing with sensing cables (Water and Acid) manufactured by OmniLeak. The primary use of these devices is to monitor one zone with a maximum of 50m leak detection sensing cables for conductive liquids. The adjustable alarm threshold helps us to adjust the sensitivity of the sensing cable connected (Water or Acid). Alarm silence button will enable to sound off. Primary Response from the OL-COST:
  • In the Event of a Leak in the sensing cable connected; an audible alarm is triggered, the leak LED (red) and the volt-free relay associated is activated
  • In the Event of a Cable Break in the sensing cable or leader cable connected; an audible alarm is triggered with the Cable Break LED (amber) and the volt-free relay associated is activated Secondary Response from the OL-COST alarm threshold (low to high)
  • High-level interfacing to BMS/DCS/SCADA is implemented through Modbus RTU or Modbus TCP

Features and Benefits

  • Standalone system to monitor maximum of 120m of sensing cable
  • Adjustable alarm threshold (low to high)
  • Audible sounder with silence button.
  • Leak location in meters, Power, Leak and Cable Break LED’s
  • Volt-free Relay contacts for:
    • Power Failure
    • Leak Alarm
    • Cable Break/Trouble
  • Remote monitoring (Modbus RS485 or TCP/IP)

Typical Applications

  • Leak detection in FCU units with standalone panel.
  • Remote areas where unmanned sites are located.
  • Installed where only the leak location is required.
  • Small rooms where only a few meters are to be protected.

Need a Liquid Leak Detection For Your Project?