OL-aSAT7 is a high-performance 7-inch touchscreen controller designed for powering and interfacing with acquisition modules manufactured by OmniLeak. The communication with these modules is based on a proprietary long-range failsafe bus. The controller is offered in IP54/NEMA 3S water-resistant wall-mounted enclosure, to be installed in technical rooms and other premises where dripping water might be potentially present. The primary use of OL-aSAT7 is to monitor one or two circuits with long detection strings for hydrocarbons, organic solvents or conductive liquids of up to 300 m each. The communication frontend permits robust and reliable operation even in case of partial failure of the circuit of acquisition modules. Each individual acquisition module is connected to an independent sensor and the system provides true multi-leak capability. All compatible acquisition modules are powered by the terminal through the proprietary bus and the need of additional infrastructure is considerably reduced. The maximum distance covered with this wired layout (accumulated sensor and jumper cables) is in excess of 1 km. The optional loopback wiring increases the system reliability in case of cable breaks and shorts.
The intuitive password-protected user interface on the touch panel provides flexible configuration and adjustable alarm threshold. High-level interfacing to BMS/DCS/SCADA is implemented through Modbus RTU, Modbus TCP, email alerts and SNMP Traps. Configurable dry contacts (number 12) for general alarm, leak alarm, power failure and trouble are also available.

Features and Benefits

Typical Applications

Compatible Acquisition Modules and Remote Devices

OL-HCM
123
Acquisition module for detecting unwanted presence of hydrocarbons in indoor environment. Maximum length of sensor string per acquisition module: 15 m
OL-SLDM
456
Acquisition module for detecting unwanted presence of hydrocarbons in indoor environment. Maximum length of sensor string per acquisition module: 15 m
OL-WS2R
12ws
Acquisition module for detecting unwanted presence of hydrocarbons in indoor environment. Maximum length of sensor string per acquisition module: 15 m

Technical Data

Display Size and Resolution
7-in TFT, 800 x 480
Dimensions
295 x 260 x 125 mm (11.61 x 10.24 x 4.92 in.)
Weight
1.3 kg (3 lb.)
Fire Rating
UL94-HB (UL94-V0 available on request)
Ingress Rating
IP54/NEMA 3S – indoor use only (IP65/NEMA 4 available on request)
Operating Temperature Range
0°C to +50°C
Power Supply Input
100-240VAC or 24VDC
Maximum Length of Cable
Accumulated length of Sensor and Lead Cables per channel: 1 km
Power Consumption
18.5W max.
Installation
Wall-mounted

Product Codes

OL-aSAT7
Dual-channel alarm terminal for circuits with a maximum of 10 acquisition modules each, with Modbus RTU/TCP, SNMP Traps and 12 SPDT relay outputs
OL-aSAT-12R-485
Dual-channel remote alarm terminal without display with a maximum of 10 acquisition modules each, with Modbus RTU and 12 SPDT relay outputs
OL-aSAT-12R-TCP
Dual-channel remote alarm terminal without display with a maximum of 10 acquisition modules each, with Modbus TCP and 12 SPDT relay outputs

Manufacturer

OmniLeak address

Certifications